<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-08 08-17-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 74 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 68 kHz 18914 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,0 dBr 6,04 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Bonnie Tyler - It's a heartache "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 68 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/12/08 8.16.28 Total samples: 18914 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 5,0 dBr AVE: 6,04 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2024/12/08 8.16.27) 08.02 08.04 08.06 08.08 08.10 08.12 08.14 08.16 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]